Altium

Electrical Rule Check Report

Date: 16.08.2023
Time: 9:35:49
Filename: C:\Users\fg77rg\Userdata\_backup\Altium\projects\_RainLight\R124_EVK_V31\Project Outputs\R124_EVK_V31 - Electrical Rules Check.html
Class Document Message
Warning R124_EVK_V31_Top.SchDoc Net CSB has no driving source (Pin R9-2, Pin TP_CSB-1, Pin U1-9)
Warning R124_EVK_V31_Top.SchDoc Net EN has no driving source (Pin J11-2, Pin J12-1, Pin J_SPI_IO1-8, Pin TP_EN-1, Pin U1-8)
Warning R124_EVK_V31_Top.SchDoc Net MOSI has no driving source (Pin R6-2, Pin TP_MOSI-1, Pin U1-10)
Warning R124_EVK_V31_Top.SchDoc Net SCK has no driving source (Pin R7-2, Pin TP_SCK-1, Pin U1-11)
Warning R124_EVK_V31_Top.SchDoc Nets Wire CSB has multiple names (Net Label CSB (3), Sheet Entry U_Device-SPI.CSB(Passive), Sheet Entry U_MCU-SPI.CSB(Passive))
Warning R124_EVK_V31_Top.SchDoc Nets Wire MISO has multiple names (Net Label MISO (3), Sheet Entry U_Device-SPI.MISO(Passive), Sheet Entry U_MCU-SPI.MISO(Passive))
Warning R124_EVK_V31_Top.SchDoc Nets Wire MOSI has multiple names (Net Label MOSI (3), Sheet Entry U_Device-SPI.MOSI(Passive), Sheet Entry U_MCU-SPI.MOSI(Passive))
Warning R124_EVK_V31_Top.SchDoc Nets Wire SCK has multiple names (Net Label SCK (3), Sheet Entry U_Device-SPI.SCK(Passive), Sheet Entry U_MCU-SPI.SCK(Passive))

Back to top